Made In Great Britain

Direct from our factory

Product Test Results

All test results published

Expert Technical Advice

Call or chat with our team

Overview

Overview ⓘ

VOC content is the amount of volatile organic compounds in a coating, in grams per litre of product ready to use. It is measured by ISO 11890 and limited by law for each category of paint.

VOC stands for volatile organic compound. In a coating these are mostly the solvents that evaporate as the film dries. VOC content states how much of them the product contains.

What the test measures

The test measures the mass of volatile organic compounds in a litre of the product as it is used. The result is given in grams per litre, written g/l.

The legal definition is specific. It comes from Directive 2004/42/EC, the source of the paint products rules. A VOC is any organic compound with an initial boiling point of 250 °C or below, at standard pressure. Water is not a VOC.

How the test is carried out

The methods are in ISO 11890. Which part is used depends on how much VOC is expected.

Method Used when How it works
ISO 11890-2 VOC content is between about 0.1% and 15% by mass Gas chromatography. The volatile compounds are separated, identified and measured one by one.
ISO 11890-1 VOC content is above about 15% by mass The difference method. The sample is heated and the loss in mass is measured, with the water content taken off.

For a two-part product, the figure is for the mixed material, in the ratio it is used.

How to read the result

Lower means less solvent is released as the coating dries.

The law sets a maximum for each category of coating, and the limits differ between categories and between water-based and solvent-based products. A figure is read against the limit for its own category. The category and its limit are printed on the tin.

What it means in use

  • Indoors. A low-VOC coating puts less solvent vapour into the air of a closed space while it dries.
  • Odour. Less solvent generally means less smell during application, though odour and VOC content are not the same thing.
  • Specification. Many building standards and client specifications set a VOC ceiling for the products used.

What the result does not tell you

VOC content is not a hazard rating. A product low in VOC can still carry hazard classifications for other reasons. The safety data sheet is the document for hazards, and it should be read whatever the VOC figure.

The figure is the content of the wet product. It does not measure what a cured film gives off over the following weeks, which is a different test.

It also says nothing about how the coating performs. Water-based and solvent-based products are chosen for their properties as well as their VOC content.

On our product pages

Where a product has been tested, its page shows the result, the method and, where the method has one, the rating. Results published on this site come from internal testing to the stated method. They are given for technical reference and comparison.

If a figure you need is not shown, ask our technical team.

Latest Stories

This section doesn’t currently include any content. Add content to this section using the sidebar.